How to match a chiller with an injection molding machine
How to match a chiller with an injection molding machine
The matching of domestic vertical and horizontal injection molding machines under normal environmental temperature usage, when the cooling water condensation temperature of the water-cooled chiller is below 35 degrees Celsius (the condensation temperature of the air-cooled chiller is below 43 degrees Celsius).
A: The first method:
The 1HP water-cooled chiller can be equipped with an 80 ton locking force injection molding machine with a temperature control of 5-10 degrees Celsius;
The 1HP water-cooled chiller can be equipped with a 100 ton mold locking force injection molding machine with a temperature control of 10-15 degrees;
The 1HP water-cooled chiller can be equipped with a 120 ton mold locking force injection molding machine with a temperature control of 15-20 degrees;
(The matching of air-cooled chillers is 0.8 times that of water-cooled chillers, which means that the 1HP air-cooled chiller can be equipped with an injection molding machine with a locking force of 64 tons, and the temperature is controlled at 5-10 degrees Celsius.)
B: The second method:
The 1HP water-cooled chiller can be equipped with an injection molding machine with a single injection volume of 10 QZ, with a temperature control of 5-10 degrees Celsius
Injection quantity 1QZ=28.5g
The above formula is a summary of the experience. In addition to using the above formula, salespeople should consider the actual situation and choose a suitable chiller
C: Matching of chillers and cooling towers,
According to past experience, a 1 HP chiller requires a 1.2 ton cooling tower to take away the heat generated by the chiller.
|